C. Nadeau and A. Krupa, Intensity-based direct visual servoing of an ultrasound probe, 2011 IEEE International Conference on Robotics and Automation, 2011.
DOI : 10.1109/ICRA.2011.5979673

URL : https://hal.archives-ouvertes.fr/hal-00639689

C. Nadeau and A. Krupa, Improving ultrasound intensity-based visual servoing: tracking and positioning tasks with 2D and bi-plane probes, IEEE/RSJ Int. Conf. on Intelligent Robots and Systems, 2011.
DOI : 10.1109/iros.2011.6094886

URL : https://hal.archives-ouvertes.fr/hal-00639692

J. Hong, T. Dohi, M. Hashizume, K. Konishi, and N. Hata, A Motion Adaptable Needle Placement Instrument Based on Tumor Specific Ultrasonic Image Segmentation, 5th Int. Conf. on Medical Image Computing and Computer Assisted Intervention, MICCAI'02, pp.122-129, 2002.
DOI : 10.1007/3-540-45786-0_16

P. M. Novotny, J. A. Stoll, P. E. Dupont, and R. D. Howe, Real-Time Visual Servoing of a Robot Using Three-Dimensional Ultrasound, Proceedings 2007 IEEE International Conference on Robotics and Automation, pp.2655-2660, 2007.
DOI : 10.1109/ROBOT.2007.363866

M. A. Vitrani, H. Mitterhofer, N. Bonnet, and G. , Robust ultrasoundbased visual servoing for beating heart intracardiac surgery, IEEE Int. Conf. on Robotics and Automation, ICRA'07, pp.3021-3027, 2007.
DOI : 10.1109/robot.2007.363931

URL : https://hal.archives-ouvertes.fr/hal-01170711

M. Sauvee, P. Poignet, and E. Dombre, US image based visual servoing of a surgical instrument through non-linear model predictive control, Int. Journal of Robotics Research, vol.27, issue.1, 2008.

P. Abolmaesumi, S. Salcudean, W. Zhu, M. Sirouspour, and S. Dimaio, Image-guided control of a robot for medical ultrasound, IEEE Transactions on Robotics and Automation, vol.18, issue.1, 2002.
DOI : 10.1109/70.988970

D. Lee, N. Koizumi, K. Ota, S. Yoshizawa, A. Ito et al., Ultrasound-based visual servoing system for lithotripsy, IEEE/RSJ Int. Conf. on Intelligent Robots and Systems, IROS'07, pp.877-882, 2007.

R. Mebarki, A. Krupa, and F. Chaumette, 2-D Ultrasound Probe Complete Guidance by Visual Servoing Using Image Moments, IEEE Transactions on Robotics, vol.26, issue.2, pp.296-306, 2010.
DOI : 10.1109/TRO.2010.2042533

URL : https://hal.archives-ouvertes.fr/inria-00544791

N. Friedland and D. Adam, Automatic ventricular cavity boundary detection from sequential ultrasound images using simulated annealing, IEEE Transactions on Medical Imaging, vol.8, issue.4, pp.344-353, 1989.
DOI : 10.1109/42.41487

C. Nadeau and A. Krupa, A multi-plane approach for ultrasound visual servoing: Application to a registration task, 2010 IEEE/RSJ International Conference on Intelligent Robots and Systems, 2010.
DOI : 10.1109/IROS.2010.5651463

URL : https://hal.archives-ouvertes.fr/inria-00544792

C. Collewet and E. Marchand, Photometric Visual Servoing, IEEE Transactions on Robotics, vol.27, issue.4, pp.828-834, 2011.
DOI : 10.1109/TRO.2011.2112593

URL : https://hal.archives-ouvertes.fr/inria-00319107

]. A. Krupa, G. Fichtinger, and G. Hager, Real-time Motion Stabilization with B-mode Ultrasound Using Image Speckle Information and Visual Servoing, The International Journal of Robotics Research, vol.26, issue.4
DOI : 10.1177/0278364909104066

URL : https://hal.archives-ouvertes.fr/inria-00436745

F. Chaumette and S. Hutchinson, Visual servo control. I. Basic approaches, IEEE Robotics & Automation Magazine, vol.13, issue.4, pp.82-90, 2006.
DOI : 10.1109/MRA.2006.250573

URL : https://hal.archives-ouvertes.fr/inria-00350638

L. Mercier, T. Lango, F. Lindseth, and L. D. Collins, A review of calibration techniques for freehand 3-D ultrasound systems, Ultrasound in Medicine & Biology, vol.31, issue.2, pp.143-165, 2005.
DOI : 10.1016/j.ultrasmedbio.2004.11.001

V. Acary and B. Brogliato, Numerical Methods for Nonsmooth Dynamical Systems: Applications in Mechanics and Electronics, p.114, 2008.
URL : https://hal.archives-ouvertes.fr/inria-00423530

M. Hadwiger, J. M. Kniss, C. Rezk-salama, D. Weiskopf, and K. Engel, Real-time Volume Graphics, pp.112-114, 2006.

M. De-mathelin and R. Lozano, Robust adaptive identification of slowly time-varying parameters with bounded disturbances, Automatica, vol.35, issue.7, pp.1291-1305, 1999.
DOI : 10.1016/S0005-1098(99)00026-6

W. Schroeder, K. Martin, and B. Lorensen, The Visualization Toolkit, 2003.
DOI : 10.1016/B978-012387582-2/50032-0

E. Marchand, F. Spindler, and F. Chaumette, ViSP for visual servoing: a generic software platform with a wide class of robot control skills, IEEE Robotics & Automation Magazine, vol.12, issue.4, pp.40-52, 2005.
DOI : 10.1109/MRA.2005.1577023

URL : https://hal.archives-ouvertes.fr/inria-00351899

J. D. Schutter, T. De-laet, J. Rutgeerts, W. Decr, R. Smits et al., Constraint-based Task Specification and Estimation for Sensor-Based Robot Systems in the Presence of Geometric Uncertainty, The International Journal of Robotics Research, vol.10, issue.2, pp.433-455, 2007.
DOI : 10.1177/027836490707809107

J. Gangloff, R. Ginhoux, M. De-mathelin, L. Soler, and J. Marescaux, Model predictive control for compensation of cyclic organ motions in teleoperated laparoscopic surgery, IEEE Transactions on Control Systems Technology, vol.14, issue.2, 2006.
DOI : 10.1109/TCST.2005.863650

M. C. Corretti, T. J. Anderson, E. J. Benjamin, D. Celermajer, F. Charbonneau et al., Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery, Journal of the American College of Cardiology, vol.39, issue.2, pp.257-265, 2002.
DOI : 10.1016/S0735-1097(01)01746-6