OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement, IEEE Transactions on Biomedical Engineering, vol.54, issue.11, pp.1940-1950, 2007. ,
DOI : 10.1109/TBME.2007.901024
The coordination of arm movements: an experimentally confirmed mathematical model, JNeurosci1985, vol.5, issue.7, pp.1688-1703 ,
Trajectory formation of arm movement by cascade neural network model based on minimum torque-change criterion, Biological Cybernetics, vol.1, issue.4, pp.275-288, 1990. ,
DOI : 10.1007/BF00201442
Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report, IEEE Transactions on Rehabilitation Engineering, vol.7, issue.4, pp.390-398, 1999. ,
DOI : 10.1109/86.808942
An implantable neuroprosthesis for standing and walking in paraplegia: 5-year patient follow-up, Journal of Neural Engineering, vol.3, issue.4, pp.268-275, 2006. ,
DOI : 10.1088/1741-2560/3/4/003
Surface EMG models: properties and applications, Journal of Electromyography and Kinesiology, vol.10, issue.5, pp.313-326, 2000. ,
DOI : 10.1016/S1050-6411(00)00023-7
Neuromusculoskeletal Modeling: Estimation of Muscle Forces and Joint Moments and Movements from Measurements of Neural Command, Journal of Applied Biomechanics, vol.20, issue.4, pp.367-395, 2004. ,
DOI : 10.1123/jab.20.4.367
An EMG-driven musculoskeletal model to estimate muscle forces and knee joint moments in vivo, Journal of Biomechanics, vol.36, issue.6, pp.765-776, 2003. ,
DOI : 10.1016/S0021-9290(03)00010-1
Feasibility of using EMG driven neuromusculoskeletal model for prediction of dynamic movement of the elbow, Journal of Electromyography and Kinesiology, vol.15, issue.1, pp.12-26, 2005. ,
DOI : 10.1016/j.jelekin.2004.06.007
The Heat of Shortening and the Dynamic Constants of Muscle, Proceedings of the Royal Society B: Biological Sciences, vol.126, issue.843, pp.136-195, 1938. ,
DOI : 10.1098/rspb.1938.0050
Muscle and tendon: properties, models, scaling and application to biomechanics and motor control, CRC Critic Rev Biomed Eng, vol.17, pp.359-411, 1989. ,
Hill muscle model errors during movement are greatest within the physiologically relevant range of motor unit firing rates, Journal of Biomechanics, vol.36, issue.2, pp.211-218, 2003. ,
DOI : 10.1016/S0021-9290(02)00332-9
A one-parameter neural activation to muscle activation model: estimating isometric joint moments from electromyograms, Journal of Biomechanics, vol.36, issue.8, pp.1197-1202, 2003. ,
DOI : 10.1016/S0021-9290(03)00152-0
Muscle structure and theories of contraction, Prog Biophys Biophys Chem, vol.7, pp.255-318, 1957. ,
Optimum power output and structural design of sarcomeres, Journal of Theoretical Biology, vol.149, issue.2, pp.229-256, 1991. ,
DOI : 10.1016/S0022-5193(05)80279-6
A distribution-moment approximation for kinetic theories of muscular contraction, Mathematical Biosciences, vol.55, issue.1-2, pp.89-114, 1981. ,
DOI : 10.1016/0025-5564(81)90014-6
A Biomechanical Model of Muscle Contraction, Proc Int Conf Med Image Comput Comput-Assist Intervent MICCAI 2001, pp.1159-1161, 2001. ,
DOI : 10.1007/3-540-45468-3_143
Erratum to: Multiscale modeling of skeletal muscle properties and experimental validations in isometric conditions, Biological Cybernetics, vol.105, issue.2, pp.121-138, 2011. ,
DOI : 10.1007/s00422-011-0453-7
EMG-to-force estimation with full-scale physiology based muscle model, 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems, pp.1621-1626, 2009. ,
DOI : 10.1109/IROS.2009.5354644
URL : https://hal.archives-ouvertes.fr/lirmm-00429594
European recommendations for surface electromyography, results of the seniam project The Netherlands: Roessingh Research and Development, 1999. ,
Optimal muscle fascicle length and tendon stiffness for maximising gastrocnemius efficiency during human walking and running, Journal of Theoretical Biology, vol.252, issue.4, pp.662-673, 2008. ,
DOI : 10.1016/j.jtbi.2008.01.018
Learning combined feedback and feedforward control of a musculoskeletal system, Biological Cybernetics, vol.32, issue.6, pp.73-83, 1996. ,
DOI : 10.1007/BF00238741
Impedance characteristics of a neuromusculoskeletal model of the human arm I. Posture control, Biological Cybernetics, vol.81, issue.5-6, pp.475-494, 1999. ,
DOI : 10.1007/s004220050577
Surgery simulation: a computer graphics system to analyze and design musculoskeletal reconstructions of the lower limb, 1990. ,
Mathematical Physiology, II: Systems Physiology, 2009. ,
Modele Differentiel de la Contraction Musculaire controlee application au system cardio-vasculaire, 2000. ,
A method for determining lower extremity muscle-tendon lengths during flexion/extension movements, Journal of Biomechanics, vol.23, issue.5, pp.487-494, 1990. ,
DOI : 10.1016/0021-9290(90)90304-L
Measurement of muscle and tendon stiffness in man, European Journal of Applied Physiology and Occupational Physiology, vol.347, issue.4, pp.380-382, 1996. ,
DOI : 10.1007/BF00599700
In vivo identification of skeletal muscle dynamics with nonlinear Kalman filter: comparison between EKF and SPKF ,
URL : https://hal.archives-ouvertes.fr/lirmm-00835852
Experimental parameter identification of a multi-scale musculoskeletal model controlled by electrical stimulation: application to patients with spinal cord injury, Medical & Biological Engineering & Computing, vol.17, issue.6, pp.51617-631 ,
DOI : 10.1007/s11517-013-1032-y
URL : https://hal.archives-ouvertes.fr/hal-00908533