Sparse Bayesian registration of medical images for self-tuning of parameters and spatially adaptive parametrization of displacements - Inria - Institut national de recherche en sciences et technologies du numérique Accéder directement au contenu
Article Dans Une Revue Medical Image Analysis Année : 2017

Sparse Bayesian registration of medical images for self-tuning of parameters and spatially adaptive parametrization of displacements

Résumé

We extend Bayesian models of non-rigid image registration to allow not only for the automatic determination of registration parameters(such as the trade-off between image similarity and regularization functionals), but also for a data-driven, multiscale, spatially adaptive parametrization of deformations. Adaptive parametrizations have been used with success to promote both the regularity and accuracy of registration schemes, but so far on non-probabilistic grounds – either as part of multiscale heuristics, or on the basis of sparse optimization. Under the proposed model, a sparsity-inducing prior on transformation parameters complements the classical smoothness-inducing prior, and favors parametrizations that use few degrees of freedom. As a result, finer bases get introduced only in the presence of coherent image information and motion, while coarser bases ensure better extrapolation of the motion to textureless, uninformative regions. The space of possible parametrizations consists of arbitrary combinations of basis functions chosen among any preset, widely overcomplete (and typically multiscale) dictionary. Inference is tackled in an efficient Variational Bayes framework. In addition we propose a flexible mixture-of-Gaussian model of data that proves to be more faithful for a variety of image modalities than the sum-of-squared differences. The performance of the proposed approach is demonstrated on time series of (cine and tagged) magnetic resonance and echocardiographic cardiac images. The proposed algorithm matches the state-of-the-art on benchmark datasets evaluating accuracy of motion and strain, and is highly automated.
Fichier principal
Vignette du fichier
lefolgoc2016MedIA-accepted-HAL-version.pdf (7.37 Mo) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01149544 , version 1 (07-05-2015)
hal-01149544 , version 2 (22-09-2016)

Licence

Paternité - Pas d'utilisation commerciale - Pas de modification

Identifiants

Citer

Loïc Le Folgoc, Hervé Delingette, Antonio Criminisi, Nicholas Ayache. Sparse Bayesian registration of medical images for self-tuning of parameters and spatially adaptive parametrization of displacements. Medical Image Analysis, 2017, 36, pp.79 - 97. ⟨10.1016/j.media.2016.09.008⟩. ⟨hal-01149544v2⟩
864 Consultations
590 Téléchargements

Altmetric

Partager

Gmail Facebook X LinkedIn More