S. Abboud and D. Sadeh, The use of cross-correlation function for the alignment of ECG waveforms and rejection of extrasystoles, Computers and Biomedical Research, vol.17, issue.3, pp.258-266, 1984.
DOI : 10.1016/S0010-4809(84)80017-8

A. L. Goldberger, L. A. Amaral, L. Glass, J. M. Hausdorff, P. C. Ivanov et al., PhysioBank, PhysioToolkit, and PhysioNet : Components of a New Research Resource for Complex Physiologic Signals, Circulation, vol.101, issue.23, pp.215-220, 2000.
DOI : 10.1161/01.CIR.101.23.e215

B. Kohler, C. Hennig, and R. Orglmeister, The principles of software QRS detection, IEEE Engineering in Medicine and Biology Magazine, vol.21, issue.1, pp.42-57, 2002.
DOI : 10.1109/51.993193

P. Laguna, R. Jané, and P. Caminal, Automatic Detection of Wave Boundaries in Multilead ECG Signals: Validation with the CSE Database, Computers and Biomedical Research, vol.27, issue.1, pp.45-60, 1994.
DOI : 10.1006/cbmr.1994.1006

P. Laguna, R. G. Mark, A. Goldberger, and G. B. Moody, A database for evaluation of algorithms for measurement of QT and other waveform intervals in the ECG, Computers in Cardiology 1997, pp.673-676, 1997.
DOI : 10.1109/CIC.1997.648140

T. Last, C. D. Nugent, and F. J. Owens, Multi-component based cross correlation beat detection in electrocardiogram analysis, BioMedical Engineering OnLine, vol.3, issue.26, 2004.

C. Li, C. Zheng, T. , and C. , Detection of ECG characteristic points using wavelet transforms, IEEE Transactions on Biomedical. Engineering, vol.42, issue.1, pp.21-28, 1995.

K. G. Lindecrantz and H. Lilja, New software QRS detector algorithm suitable for real time applications with low signal-to-noise ratios, Journal of Biomedical Engineering, vol.10, issue.3, pp.280-284, 1988.
DOI : 10.1016/0141-5425(88)90012-X

M. Malik and A. J. Camm, Computer model of cardiac repolarization processes and of the recovery sequence, Computers and Biomedical Research, vol.22, issue.2, pp.160-80, 1989.
DOI : 10.1016/0010-4809(89)90023-2

J. P. Martínez, R. Almeida, S. Olmos, A. P. Rocha, and P. Laguna, A Wavelet-Based ECG Delineator: Evaluation on Standard Databases, IEEE Transactions on Biomedical Engineering, vol.51, issue.4, pp.570-581, 2004.
DOI : 10.1109/TBME.2003.821031

J. Moss, P. Schwartz, R. Crampton, E. Locati, C. et al., The long QT syndrome: a prospective international study, Circulation, vol.71, issue.1, pp.17-21, 1985.
DOI : 10.1161/01.CIR.71.1.17

R. Padrini, G. Butrous, A. J. Camm, and M. Malik, Algebraic Decomposition of the TU Wave Morphology Patterns, Pacing and Clinical Electrophysiology, vol.40, issue.12, pp.2209-2215, 1995.
DOI : 10.1016/0002-9149(64)90072-4

P. J. Schuartz and S. Wolf, QT interval prolongation as predictor of sudden death in patients with myocardial infarction, Circulation, vol.57, issue.6, pp.1074-1079, 1978.
DOI : 10.1161/01.CIR.57.6.1074

P. Strumillo, Nested median filtering for detecting T-wave offset in ECGs, Electronics Letters, vol.38, issue.14, pp.682-683, 2002.
DOI : 10.1049/el:20020499

J. Vila, Y. Gang, J. Presedo, M. Fernández-delgado, S. Barro et al., A new approach for TU complex characterization, IEEE Transactions on Biomedical Engineering, vol.47, issue.6, pp.47764-772, 2000.
DOI : 10.1109/10.844227

Q. Zhang, Matlab package for robust and efficient location of T-wave ends in ECG and its evaluation with PhysioNet data, 2005.