C. Y. Liu, M. Y. Apuzzo, and M. L. , The physics of image formation in the neuroendoscope, Child's Nervous System, vol.40, issue.11-12, pp.777-782, 2004.
DOI : 10.1007/s00381-004-0930-6

N. T. Berlinger, Robotic Surgery ??? Squeezing into Tight Places, New England Journal of Medicine, vol.354, issue.20, 2006.
DOI : 10.1056/NEJMp058233

W. E. Smith, N. Vakil, and S. A. Maislin, Correction of distortion in endoscope images, IEEE Transactions on Medical Imaging, vol.11, issue.1, 1992.
DOI : 10.1109/42.126918

H. Haneishi, Y. Yagihashi, and Y. Miyake, A new method for distortion correction of electronic endoscope images, IEEE Transactions on Medical Imaging, vol.14, issue.3, 1995.
DOI : 10.1109/42.414620

K. V. Asari, S. Kumar, and D. Radhakrishnan, A new approach for nonlinear distortion correction in endoscopic images based on least squares estimation, IEEE Trans. on Medical Imaging, 1999.

J. P. Helferty, C. Zhang, G. Mclennan, and W. E. Higgings, Videoendoscopic distortion correction and its application to virtual guidance of endoscopy, IEEE Transactions on Medical Imaging, vol.20, issue.7, 2001.
DOI : 10.1109/42.932745

A. Conrady, Decentred Lens-Systems, Monthly Notices of the Royal Astronomical Society, vol.79, issue.5, pp.384-390, 1919.
DOI : 10.1093/mnras/79.5.384

D. Brown, Decentering distortion of lenses, Photogrammetric Engineering, vol.32, pp.444-462, 1966.

R. Shahidi, M. Bas, C. Maurer, J. Johnson, E. Wilkinson et al., Implementation, calibration and accuracy testing of an image-enhanced endoscopy system, IEEE Transactions on Medical Imaging, vol.21, issue.12, 2002.
DOI : 10.1109/TMI.2002.806597

R. Tsai, A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses, IEEE Journal on Robotics and Automation, vol.3, issue.4, 1987.
DOI : 10.1109/JRA.1987.1087109

T. Yamaguchi, M. Nakamoto, Y. Sato, K. Konishi, M. Hashizume et al., Development of a camera model and calibration procedure for oblique-viewing endoscopes, Computer Aided Surgery, 2004.

C. Wuy, S. G. Narasimhany, and B. Jaramazy, Shape-from-shading under near point lighting and partial views for orthopedic endoscopy, Photometric Analysis For Computer Vision, 2007.

Z. Zhang, Flexible camera calibration by viewing a plane from unknown orientations, Proceedings of the Seventh IEEE International Conference on Computer Vision, 1999.
DOI : 10.1109/ICCV.1999.791289

J. P. Barreto, R. Swaminathan, and J. Roquette, Non Parametric Distortion Correction in Endoscopic Medical Images, 2007 3DTV Conference, 2007.
DOI : 10.1109/3DTV.2007.4379383

R. I. Hartley and S. B. Kang, Parameter-free radial distortion correction with centre of distortion estimation, Tenth IEEE International Conference on Computer Vision (ICCV'05) Volume 1, 2005.
DOI : 10.1109/ICCV.2005.184

M. D. Grossberg and S. K. Nayar, The Raxel Imaging Model and Ray-Based Calibration, International Journal of Computer Vision, vol.61, issue.2, pp.119-137, 2005.
DOI : 10.1023/B:VISI.0000043754.56350.10

J. Salvi, J. Pages, and J. Batlle, Pattern codification strategies in structured light systems, Pattern Recognition, vol.37, issue.4, pp.827-849, 2004.
DOI : 10.1016/j.patcog.2003.10.002

R. Hartley and A. Zisserman, Multiple View Geometry in Computer Vision, 2004.
DOI : 10.1017/CBO9780511811685

J. Semple and G. Kneebone, Algebraic Projective Geometry, 1998.