R. Riener and T. Fuhr, Patient-driven control of FES-supported standing up: a simulation study, IEEE Transactions on Rehabilitation Engineering, vol.6, issue.2, pp.113-124, 1998.
DOI : 10.1109/86.681177

R. Kobetic, R. J. Triolo, and E. B. Marsolais, Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia, IEEE Transactions on Rehabilitation Engineering, vol.5, issue.1, pp.23-29, 1997.
DOI : 10.1109/86.559346

R. Riener, Model-based development of neuroprostheses for paraplegic patients, pp.877-894, 1999354.

W. K. Durfee, Chapter 33 Control of standing and gait using electrical stimulation: influence of muscle model complexity on control strategy, Progr. Brain Res, vol.97, pp.369-381, 1993.
DOI : 10.1016/S0079-6123(08)62296-7

R. Davis, R. Eckouse, J. F. Patrick, and A. Delchanty, Computerized 22-channel stimulator for limb movement, Applied Neurophysiology, 1987.

N. D. Donaldson, T. A. Perkins, and A. C. Worley, Lumbar Root Stimulation for Restoring Leg Function: Stimulator and Measurement of Muscle Actions, Artificial Organs, vol.23, issue.6, 1997.
DOI : 10.1111/j.1525-1594.1997.tb04660.x

R. Kobetic, Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report, IEEE Transactions on Rehabilitation Engineering, vol.7, issue.4, 1999.
DOI : 10.1109/86.808942

D. Guiraud, B. Denis, P. Couderc, G. Taroni, and T. Stieglitz, Description of a sixteen-channel FES implantable system, 2000.

G. Alba and D. Guiraud, The use of FES for gait rehabilitation in paraplegics, 5° conference of the European Society for Engineering and Medicine, 1999.

D. Guiraud, G. Alba, and B. Gilbert, From external to implanted FES, a high technology product line, IV International conference on medical and biological new technology, pp.1-3

A. F. Huxley, Muscle structure and theory of contraction, Progress in biophysics and biological chemistry, 1957.

G. I. Zahalak, A distribution-moment approximation for kinetic theories of muscular contraction, Mathematical Biosciences, vol.55, issue.1-2, pp.55-89, 1981.
DOI : 10.1016/0025-5564(81)90014-6

J. Bestel, Modèle différentiel de la contraction musculaire contrôlée, 2000.

E. Makssoud and H. , Modèle de muscle pour BIP paraplégique, E.A. report, LIRMM, 2002.

L. Brethes, Analyse de la marche par vidéo 3D, 2002.

L. Herda, P. Fua, R. Plänkers, R. Boulic, and D. Thalmann, Using skeleton-based tracking to increase the reliability of optical motion capture, Swiss Federal Institute of Technology CH-1015
DOI : 10.1016/S0167-9457(01)00050-1

S. Sahan, . Hiniduma-udugama-gamage, and J. Lasenby, New least squares solutions for estimating the average centre of rotation and the axis of rotation, Journal of Biomechanics, vol.35, pp.87-93, 2002.

P. B. Wieber, Modélisation et commande d'un robot marcheur anthropomorphe, 2000.

B. Brogliato, Non smooth impact mechanics, 1996.

M. Guilbert, Intégration logicielle en vue d'une expérimentation en réalité virtuelle autour de la marche humaine, internal report Mines de Douai, 2002.

P. Sardain, M. Rostami, and G. Bessonnet, An anthropomorphic biped robot: dynamic concepts and technological design, IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans, vol.28, issue.6, pp.823-838, 1998.
DOI : 10.1109/3468.725353